    UB overall non-blind zone glass plate level gauge

    Overview: The glass plates of the UB-type non-blind-type glass plate level gauge are staggered on both sides of the body, and the liquid level can be continuously observed.

    1. Working principle
    2. Technical Parameters
    3. Selection table
    4. Dimension drawing
    5. Instructions for ordering

    Overview: The glass plates of the UB-type non-blind-type glass plate level gauge are staggered on both sides of the body, and the liquid level can be continuously observed.

    Measurement range (flange center distance L) 500mm,800mm,1100m,1400mm,1700mmVisible rangeH≥L
    Nominal pressure≤4.0 MPaWorking temperature-20~+250℃
    Wetted material20、304、316 or according to user requirements Heat-tracing steam jacket connectorR3 / 8 (external thread) or according to user requirements
    Non-wettable materialCarbon steelHeating steam pressure≤1 MPa
    Connecting flangeHG/T20592-2009,HG/T20615-2009 or according to user requirements





    Product parameters
    ModelDescription
    UBYaFeng Glass plate level gauge
    CategoryOmittedCork 3T      Ternary
    DChase

    Show categoriess1Monochrome    s2     Two-color
    Types ofFReflectiveTTransmissive
    Pressure Level(MPa)1.6PN1.66.3PN6.3
    2CL150LB10PN10.0
    2.5PN2.511CL600LB
    4PN4.015CL900LB
    5CL300LB16PN16.0
    RangeRange mm
    MaterialCCSolid carbon steel
    PPOverall 304
    PCWet 304,Gland carbon steel
    PLCWet 316/321,Gland carbon steel
    PLPWet 316/321,Gland 304
    PLPLWet 316/321,Gland 316
    Flange specifications15DN1540DN40
    20DN2050DN50
    25DN2565DN65
    32DN32FFFull plane
    Flange sealing surfaceOmittedRaised faceRJRing connection surface
    MConvex

    FMConcave

    InsulationOmittedno
    Bband
    TemperatureW20-250
    W40-400
    W50-500
    Glass materialGHTempering ( Pressure≤ 4.0MPa, Temperature≤ 250℃)
    GPHigh borosilicate ( Pressure≤ 8.0MPa, Temperature≤ 400℃)
    LG1Aluminum silicon 1( Pressure≤ 16.0MPa, Temperature≤ 500℃)
    LG2Aluminum silicon 2( Pressure≤ 20.0MPa, Temperature≤ 500℃)
    LG3Aluminum silicon 3( Pressure≤ 25.0MPa, Temperature≤ 500℃)
    Dead zone requirementsOmittedno
    AOrdinary no dead zone
    BSingle row interleaving
    SDouble row interleaving
    Anti-frostOmittedNo
    FWith frost protection

    UB型无盲区玻璃板液位计.jpg

    Media Name:
    Wetted material:
    Liquid gauge bit number:
    Flange specifications:
    Range:
    Flange material:
    Pressure:
    Sealing surface:

    Connection method: