Liquid level switch
UTK float level switch
Overview:UTK float level controller uses float or float as the measuring element. The measuring element is connected to the magnetic tube. When the liquid level rises, the magnetic tube moves upward i
Overview:
UTK float level controller uses float or float as the measuring element. The measuring element is connected to the magnetic tube. When the liquid level rises, the magnetic tube moves upward into the external magnetic field, and the magnetic control is attracted by magnetic induction or magnetic coupling. The switch or bias magnet makes the switch contact on or off. When the liquid level decreases, the magnet tube moves downwards, the magnet tube is separated from the external magnetic field, the magnetron switch restores the original state or the role of the bias magnet in its own weight. Down, return to the new equilibrium position, make the switch contacts on or off, to achieve the level control and alarm.
Nominal pressure | ≤16.0MPa | Measurement accuracy | Level Control:±4mm |
Boundary control | ±6mm | Flange standard | HG/T20592-2009,HG/T20615-2009 Or according to user requirements |
Ambient temperature | -40℃~+80℃ | Operating temperature | -40℃~+150℃(High temperature type:300℃) |
Medium density | Level Control: ρ≥0.5g/cm3 | Boundary control | ρ1-ρ2≥ 0.25g/cm3 |
Medium viscosity | ≤1St(10-4m2/S) | Wetted material | 20、304、316L Or according to user requirements |
Power inlet | G1 / 2 "(internal thread) or according to user requirements | Explosion-proof type | Flameproof ExdⅡCT4~T6 |
Intrinsically safe | ExiaⅡCT4~T6 | Protection class | IP67 |
Model | Description | |||
UTK | YaFeng float level controller | |||
Installation Form | C | Side Mount | D | Top Mount |
Pressure rating(MPa) | 1.0 | PN1.0MPa | 16.0 | PN16.0MPa |
1.6 | PN1.6MPa | 2.0 | CL150LB | |
2.5 | PN2.5MPa | 5.0 | CL300LB | |
4.0 | PN4.0MPa | 11.0 | CL600LB | |
6.3 | PN6.3MPa | 15.0 | CL900LB | |
10.0 | PN10.0MPa | 26.0 | CL1500LB | |
Range-density Range | mm-density g / cm 3 | |||
Top flange material | P | 304 | ||
PL | 316L | |||
P1 | 321 | |||
Float material | P | 304 | ||
PL | 316L | |||
Ti | Titanium | |||
Explosion-proof type | omit | None | ||
b | Explosion-proof type | |||
a | Intrinsically Safe | |||
Accessories | Omit | None | ||
W | Outer buoy | |||
D | Guide tube | |||
Outer buoy material | C | Carbon steel | ||
P | 304 | |||
PL | 316L | |||
P1 | 321 | |||
Outer float side flange material | 20 | DN20 | ||
25 | DN25 | |||
32 | DN32 | |||
40 | DN40 | |||
50 | DN50 | |||
65 | DN65 | |||
80 | DN80 | |||
100 | DN100 | |||
Flange sealing surface of outer buoy side | Omit | protruding surface | ||
F | convex | |||
FM | concave | |||
FF | Full plane | |||
RJ | Ring connection surface |
Model specifications: | Installation form: | ||
Working medium: | Working pressure: | ||
Operating temperature: | Flange standard: | ||
Wetted material: | Medium density: | ||